Intermediary female 12x125 to 9/16" adaptor for connecting a 12x125 outlet flowmeter to a 9/16" inlet humidifier or nebulizer.
Block 1 probe medical air with hospipe 1.50m with complete rail mounting system.
Block 2 probes for medical air with hospipe 1.5m with rail mounting system.
Block 2 probes for oxygen with hospipe 1.5m with rail mounting system.
Oxygen probe AFNOR for flowmeter and Y connector. AFNOR (french standard).
Medical air connector AFNOR for medical gases. AFNOR ( french standard)
The bubbler is a sub-assembly pre-assembled comprising a dip tube and a diffuser. This subset changes after cleaning the humidifier to avoid the presence of impurities and cleaning at the time of reactivation.
The diffuser is a porous element through which the oxygen is transformed in fine bubbles. This increasing the exchange surface with water. The oxygen is then moisturized for confortable inhalation.
The dip tube silicone heat oxygen inlet connection to the diffuser.
The Dexther medical air flowmeter is used to fix a gas flow value corresponding to the medical prescription. It is connected to terminal units of medical gas distribution systems. CONNECTOR AFNOR - DIN - BSI
The Dexther flowmeter is used to fix a gas flow value corresponding to the medical prescription. It is connected to terminal units of medical gas distribution systems. Supply pressure : 4,5 bar (+/- 0.5bar). Connection tip : AFNOR - DIN - BSI.
The connecting hospipes for low-pressure medical gas DEXTHER comply with the Medical Devices Directive 93/42/EEC. Compliance with the Medical Devices Directive 93/42/EEC. is based on NFS 90-116 and EN ISO 9170-1 standards.
The DEXTHER humidifier is designed for medical use oxygen therapy to reduce drying of mucous membranes caused by pure oxygen. It is advisable when the oxygen pressure is greater than 5 bar. It is connected to such pressure reducers, flowmeters, to concentators....
Medical Air Y connector DEXTHER can double the gas outlet for connecting multiple devices.
The connecting hospipes for low-pressure medical gas DEXTHER comply with the Medical Devices Directive 93/42/EEC. Compliance with the Medical Devices Directive 93/42/EEC is based on NFS 90-116 and EN ISO 9170-1 standards. PROBES AFNOR - DIN - BSI
The DEXTHER oxygen Humidifier is designed for medical use oxygen therapy to reduce drying of mucous membranes caused by pure oxygen. It is advisable when the oxygen pressure is greater than 5 bar. It is connected to such pressure reducers, flowmeters, to concentators....
Oxygen Y connector Dexther can double the gas outlet for connecting multiple devices.